COAXIAL/R-2YCCH 1x0.50 S
 
	 
	 
	Description 
	Tinned copper conductor. Polyethylene insulation. Tinned copper braid shield. 
	Tinned copper braid shield. Halogen free compound outer sheath. 
	  
	
		
			| PHYSICAL CHARACTERISTICS | 
		 
		
			| Conductor | 
		 
		
			|     Material | 
			Tinned Copper  | 
		 
		
			|     Section (mm2) | 
			0,20 | 
		 
		
			|     AWG | 
			24 | 
		 
		
			|     Composition | 
			1x0,50 | 
		 
		
			| Insulation | 
		 
		
			|     Material | 
			Polyethylene | 
		 
		
			|     Diameter(mm) | 
			2,90 | 
		 
		
			|     Colour | 
			Natural | 
		 
		
			| Shield | 
		 
		
			|     1st Shield | 
		 
		
			|    - Material | 
			Tinned copper | 
		 
		
			|    -Coverage | 
			83% | 
		 
		
			|     2nd Shield | 
		 
		
			|    - Material | 
			Tinned copper braid | 
		 
		
			|    - Coverage | 
			84% | 
		 
		
			| Outer Sheath | 
		 
		
			|     Material | 
			Halogen free compound | 
		 
		
			|     Diameter (mm) | 
			4,90 | 
		 
		
			|     Colour | 
			Grey | 
		 
		
			| MECHANICAL CHARACTERISTICS | 
		 
		
			|     Appox. Weight | 
			38 Kg/km | 
		 
		
			|     Operating temperature range | 
			-40 / +80 | 
		 
		
			|     Minimum bending radius | 
			98 mm | 
		 
		
			| ELECTRICAL CHARACTERISTICS | 
		 
		
			|     Conductor DC resistance at 20º C | 
			94,2 Ohms/km | 
		 
		
			|     Shield DC resistance at 20º C | 
			9,9 Ohms/Km | 
		 
		
			|     Nominal capacitance | 
			70 pF/m | 
		 
		
			|     Nominal impedance | 
			75 ohms | 
		 
		
			|      Velosity of propagation | 
			 66% | 
		 
		
			|     Attenuation Frequency (MHz) | 
			dB/100 m | 
		 
		
			| 1 | 
			1,4 | 
		 
		
			| 4 | 
			2,8 | 
		 
		
			| 10 | 
			4,5 | 
		 
		
			| 50 | 
			10,6 | 
		 
		
			| 70 | 
			12,8 | 
		 
		
			|     Return loss Frequency (MHz) | 
			dB | 
		 
		
			| 0-8000 | 
			20 | 
		 
		
			| 800-1000 | 
			23 | 
		 
		
			|     Insulation resistance | 
			>5000 Mohms * Km | 
		 
		
			|     Voltage test | 
			1500 v | 
		 
		
			| SAFETY Flame Test | 
		 
		
			|     Test for vertical flame spread | 
			IEC-60332-1 | 
		 
		
			|     Test for vertical flame spread | 
			IEC-60332-2 | 
		 
		
			|     Test for vertical flame spread | 
			IEC-60332-3 | 
		 
		
			|     It does not emite toxic fumes or halogens | 
			IEC-754-1 | 
		 
		
			|     It does not emite corrosive fumes or halogens | 
			IEC-754-2 | 
		 
		
			|     Low emision of dense fumes | 
			IEC-1034-1 | 
		 
		
			| ENVIRONMENT | 
		 
		
			|      Content of hazardous sustances | 
			Directive 2002/95/CE | 
		 
		
			| APPLICABLE SPECIFICATIONS | 
		 
		
			|     Conductor material | 
			UNE-EN 60228 | 
		 
		
			|     Insulation material | 
			UNE-EN 50290 | 
		 
	
  |