|  Stock Code | 
					 Description | 
				 
				
					|  101-W240-060 | 
					 WEB-240 50ohm Low Loss Coaxial Cable PE Black Class Fca | 
				 
				
					|  101-W240LZ-060 | 
					 WEB-240 50ohm Low Loss Coaxial Cable LSNH Black Class Dca | 
				 
			
		 
		
		
			
				
				 
				
					| Product Construction | 
				 
				
					| Conductor Material: | 
					Plain Annealed Copper | 
				 
				
					| Conductor Stranding: | 
					Solid 1/1.42mm | 
				 
				
					| Dielectric Material: | 
					Foam Polyethylene (FPE) | 
				 
				
					| Dielectric Diameter: | 
					3.81mm ± 0.15 | 
				 
				
					| Screen 1: | 
					Overall Bonded Aluminium Foil | 
				 
				
					| Screen 1 Coverage: | 
					>100% ± 0.1 
						 | 
				 
				
					| Screen 2: | 
					Tinned Copper Wire Braid | 
				 
				
					| Screen 2 Coverage: | 
					>90% ± 0.1 | 
				 
				
					| Sheath Material: | 
					PE / LSNH 
						 | 
				 
				
					| Sheath Colour: | 
					Black 
						 | 
				 
				
				 
				
				 
				
					| Mechanical Characteristics | 
				 
				
					| Overall Diameter: | 
					6.1mm ± 0.15mm | 
				 
				
					| Temperature Range: | 
					Fixed -15ºC to +70ºC, Flexing -5ºC to +70ºC | 
				 
				
					| Blend Radius: | 
					10 x Overall Diameter | 
				 
				
					| Weight: | 
					61kg/km | 
				 
				
				 
				
					| Electrical Characteristics | 
				 
				
					| Inner Conductor DC Resistance: | 
					≤11.5Ω/km@20ºC | 
				 
				
					| Outer Conductor  DC Resistance: | 
					≤13.5Ω/km@20ºC 
						 | 
				 
				
					| Insulation  Resistance: | 
					5000 MΩ.km | 
				 
				
					| Characteristic Impedance: | 
					50Ω ±3Ω | 
				 
				
					| Nominal Capacitance: | 
					83pF/m | 
				 
				
					| Velocity of Propagation: | 
					80% | 
				 
				
					| Peak Power: | 
					5.6kW | 
				 
				
					| Shielding Effectiveness: | 
					>90dB 
						 | 
				 
			
		 
		
		
			
				
				 
				
					|  Attenuation @ 20°C | 
				 
				
					| 
						  Frequency 
						(MHz)  | 
					
						 Attenuation 
						(per 100m)  | 
					
						  Attenuation 
						per 100ft)  | 
					
						  Power 
						kW  | 
				 
				
					| 30 | 
					4.4 | 
					1.3 | 
					1.49 | 
				 
				
					| 50 | 
					5.7 | 
					1.7 | 
					1.15 | 
				 
				
					| 150 | 
					9.9 | 
					3.0 | 
					0.66 | 
				 
				
					| 220 | 
					12.0 | 
					3.7 | 
					0.54 | 
				 
				
					| 450 | 
					17.3 | 
					5.3 | 
					0.38 | 
				 
				
					| 900  | 
					24.8 | 
					7.6 | 
					0.26 | 
				 
				
					|  1500 | 
					32.4 | 
					9.9 | 
					0.20 | 
				 
				
					|  1800 | 
					35.6 | 
					10.9 | 
					0.18 | 
				 
				
					|  2000 | 
					37.7 | 
					11.5 | 
					0.17 | 
				 
				
					|  2500 | 
					42.4 | 
					12.9 | 
					0.15 | 
				 
				
					|  5800 | 
					79.7 | 
					20.4 | 
					0.10 | 
				 
			
		 
		
		    
	
	              |